If you want an Yolin YL91F display instrument to upgrade your cmacewheel ebikes. go to cmacewheel.com to buy it.
1. PRODUCT NAME AND MODEL NUMBER……………………………………………………………………………………… 1
2. SPECIFICATION……………………………………………………………………………………………………………………….. 1
3. APPEARANCE AND SIZE……………………………………………………………………………………………………………. 1
4. FUNCTION OVERVIEW AND FUNCTIONAL AREAS……………………………………………………………………….. 3
4.1 FUNCTIONAL OVERVIEW………………………………………………………………………………………………………… 3
4.2 FUNCTIONAL AREAS………………………………………………………………………………………………………………. 3
4.3 BUTTON DEFINITIONS……………………………………………………………………………………………………………. 3
5. ROUTINE OPERATION………………………………………………………………………………………………………………. 3
5.1 POWER ON/OFF………………………………………………………………………………………………………………………. 3
5.2 DISPLAY INTERFACE SWITCHING……………………………………………………………………………………………. 4
5.3 WALK BOOST MODE………………………………………………………………………………………………………………… 5
5.4 TURNING ON/OFF LIGHTS……………………………………………………………………………………………………….. 5
5.5 PAS LEVEL SELECTION…………………………………………………………………………………………………………….. 5
5.6 BATTERY LEVEL DISPLAY…………………………………………………………………………………………………………. 6
5.7 ERROR CODE DISPLAY……………………………………………………………………………………………………………. 6
6. PERSONALIZED PARAMETER SETTINGS……………………………………………………………………………………… 6
6.1 METRIC AND IMPERIAL SETTING………………………………………………………………………………………………. 7
6.2 RATED VOLTAGE SETTING……………………………………………………………………………………………………….. 7
6.3 PAS LEVEL SETTING………………………………………………………………………………………………………………….. 8
6.4 WHEEL DIAMETER SETTING………………………………………………………………………………………………………. 8
6.5 NUMBER OF SPEED SENSOR MAGNETS SETTING………………………………………………………………………….. 9
6.6 SPEED LIMIT SETTING……………………………………………………………………………………………………………….. 9
6.7 START-UP SETTING……………………………………………………………………………………………………………….. 10
6.8 DRIVE MODE SETTING………………………………………………………………………………………………………………. 10
6.9 PEDAL ASSIST SENSITIVITY SETTING…………………………………………………………………………………………… 11
6.10 PEDAL ASSIST STRENGTH SETTING…………………………………………………………………………………………….. 11
6.11 NUMBER OF PEDAL ASSIST SENSOR MAGNETS SETTING……………………………………………………………….. 12
6.12 CONTROLLER CURRENT LIMIT SETTING………………………………………………………………………………………. 12
6.13 BATTERY UNDER VOLTAGE VALUE SETTING………………………………………………………………………………….. 13
6.14 POWER-ON PASSWORD SETTING………………………………………………………………………………………………….. 13
6.15 AUTO SLEEP TIME SETTING……………………………………………………………………………………………………….. 14
7. SHORTCUT OPERATION………………………………………………………………………………………………………………….. 15
7.1 SHORTCUT OPERATION…………………………………………………………………………………………………………………. 14
7.2 TRIP ODOMETER RESET OPERATION……………………………………………………………………………………………. 14
8. QUALITY ASSURANCE AND WARRANTY…………………………………………………………………………………………. 16
8.1 WARRANTY INFO………………………………………………………………………………………………………………………… 16
8.2 WARRANTY DOES NOT COVER…………………………………………………………………………………………………….. 16
9. WIRE CONNECTION DIAGRAM………………………………………………………………………………………………………… 16
9.1 STANDARD WIRE CONNECTION SEQUENCE……………………………………………………………………………………… 16
10. PRECAUTIONS………………………………………………………………………………………………………………………………. 16
SCHEDULE 1: ERROR CODE DEFINITION………………………………………………………………………………………………… 17
SCHEDULE 2: PEDAL ASSIST LEVEL DEFAULT RATIO VALUE…………………………………………………………………… 17
Smart LCD display for electric bicycle; Model: YL91F-V.
4.1 Functional overview
The YL91F-V display offers a variety of features to suit your riding needs, including:
The YL91F-V display is equipped with five buttons on the corresponding operating unit: power on/off, plus, minus, light, and toggle.
Long press to power on/off the display. When the display is off, it will not use the battery power and the leakage current is less than 1uA.
The display will automatically shut off if it is not used for more than 10 minutes.
5.2 Display interface switching
When the display is powered on, it will show the Current Speed (km/h) and Odometer (km) by default. Short press to switch between Odometer (km), Trip Odometer(km), Maximum Speed (km/h), and Average Speed (km/h).
Long Press and hold, the electric bicycle enters the walk boost mode. The electric bicycle will walk at a fixed speed of 6 km per hour and the display shows. Release the button to stop the power output immediately and restore it to the state before the walk boost.
The walk boost mode can only be used when pushing the electric bicycle, please do not use it while riding.
Press the to make the controller turn on the lights and the display backlight becomes dim. Press again to make the controller turn off the lights and the backlight restores brightness.
Press/to switch the PAS level of the electric bicycle, thus changing the motor output power.
Figure 5-4 PAS level display interface
The Battery level is shown as 5 bars. When the battery is fully charged, all of the 5 bars lighten up. When the battery is fully depleted, the bar will begin to flash, warning the user to charge the battery as soon as possible
If there is a fault occurs in the electronic system of the electric bicycle, the display will automatically show an error code, see Schedule 1 for a detailed definition of the error code.
When the error code appears on the display, please troubleshoot the problem in time, the electric bicycle will not be able to drive normally after the problem occurs.
Each setting needs to be done with the bicycle stationary.
The personalized parameter setting procedure is as follows:
When the display is ON and the speed shows 0
The following options are available on the personalized parameter setting interface:
P1 is the metric and imperial setting, 00 for metric and 01 for imperial.
Press to enter the parameter-changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P2 is the rated voltage setting. The available rated voltage range is: 24V, 36V, 48V, 52V.
Pressto enter the parameter changing state. Press the/ to select the parameter and press to save the parameter setting and return to the personalized parameter setting interface.
P3 is the Pedal assist (PAS) level setting. The available Pedal assist level settings are: 0~3, 1~3, 0~5, 1~5, 1~7, 0~7, 0~9, 1~9.
Press to enter the parameter-changing state. Press the /to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P4 is the wheel diameter setting. The adjustable wheel diameter range is 1~50inch.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P5 is the speed sensor magnet number setting. The adjustable speed sensor magnet number range is: 1 ~ 100 pcs.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P6 is the speed limit setting. The adjustable speed limit range is: 1~100km/h. (The maximum adjustable speed limit varies by different protocols)
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P7 is the start-up setting. The display can choose the following start modes: 00→zero start, 01→non-zero start.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P8 is the drive mode setting. The available drive modes are: 00→Pedal assist only, 01→Electric only, 02→Both Pedal assist and electric.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
P9 is the pedal assist sensitivity setting. When set to higher numbers, it will take more crank rotations to activate the motor. On lower numbers, it will take little crank rotation to activate the motor. The adjustable range is: 1~24.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
PA is the Pedal assist strength setting. The Pedal assist strength is the relative strength of the PWM signal from the controller when start to activate pedal assist. The adjustable range is 0 ~ 5. 0 is the weakest strength and 5 is the strongest.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
Pb is the number of pedal assist sensor magnets setting. The adjustable range: 1~15 pcs.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
PC is the controller current limit setting. The adjustable range is: 1~50A.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
Pd is the battery under voltage setting. The value can be adjusted based on the current rated voltage.
Pressto enter the parameter changing state. Press the/to select the parameter and pressto save the parameter setting and return to the personalized parameter setting interface.
PE is the power-on password setting. The power-on password is not activated by default but users can activate it by setting PSd-y. The factory default password is 1801 or 1212. Users can set other four-digit password. Please keep the password in mind after changing it, otherwise you will not be able to use the display.
Pressto enter the parameter changing state. Press the/ to select the parameter. PSd-y means the power-on password is activated while PSd-n is off. Pressto confirm the mode and enter the state of setting the four digits power-on password or exit to the personalized parameter setting interface.
In the password setting mode, the adjustable digit will flash. Press the/to select the parameter and press to save the numbers and go to the next digit setting. Long pressto save the parameter setting and return to the personalized parameter setting interface after finishing setting the four digits in turn.
PF is the auto sleep time setting. To save the battery power and reach higher range, this display will be turned off after it has not been used for a time. The adjustable range is: 1~60min, 00 means no auto shutdown. The factory default setting is 10 minutes.
Pressto enter the parameter changing state. Press the/to select the parameter and press to save the parameter setting and return to the personalized parameter setting interface.
dEF is the restore factory default parameter settings. dEF-Y is to restore the factory default settings, and dEF-N is not to restore.
Enter into the main setting interface and keep the speed at 0, press and holdand simultaneously for 2s to enter the restore factory default setting interface. Pressing/to toggle to dEF-Y. Then after pressingto confirm, the display will show dEF-0 for a few seconds and then automatically start to restore the factory default settings.
The display will automatically exit to setting interface after the restoration.
The display can record trip odometer and odometer. Trip odometer is not automatically reset after turning off. The trip odometer needs to be reset manually. The odometer can not be reset.
Enter into the main setting interface and keep the speed at 0, press and holdandsimultaneously for 2s to reset the trip odometer. The main interface will flash during the reset process.
Some models are equipped with waterproof connectors and the color inside wires can not be seen.
Pay attention to all the general operating when using the products and do not plug and unplug the display while it is powered on.
Download the manual:
CMACEWHEEL new color display Yolin YL91F-V-User’s Manual
If you want an Yolin YL91F display instrument to upgrade your cmacewheel ebikes. go to cmacewheel.com to buy it.